Crack Indications on Steel Forgings - Magnetic particle Inspection of forgings at Trinity NDT





Crack Indications on Steel Forgings - Magnetic particle Inspection of forgings at Trinity NDT

Technique: Magnetic particle testing using Prod Type Technique

Current: AC - 700A at 150mm prod spacing

Particle type: Fluorescent -Magnaflux make Wet

Particle concentration: 0.3 ml /100ml

Black light intensity: 1200 microwatt/cm sq. verified by calibrated Radiometer

Type of magnetization: Circular